EasyManua.ls Logo

Matrix L33-ER - TECHNICAL CHARACTERISTICS; Reference Standards and Safety Classification; Overall Dimensions and Weight; Power Supply and Electrical Specifications

Matrix L33-ER
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
Depth Widht Height Surface area Weight of tanning machine
60in 91in 71in
4 points 8x0,8in 1940lb
Power
supply
Power supply
frequency
Active power
absorption
Maximum upwards varia-
tion in power absorbed
Power factor
(cos !)
Operating
cycle
230V ± 10%, 60Hz
L33ER
+ 10%
between
0,9 and 1
30 min ON
4 min OFF
20kW
230V 3~
230V ~
(at nominal voltage
and normal operating
temperature)
Main circuit braker
breaking
capacity
circuit breaker for
auxiliary circuit
Shunt trip
L33ER L33ER L33ER L33ER
80 A with 230V
6kA
16A
On starting up of
current
Expelled hot air Delta temperature Flexible tubes n°/diameter/lenght Expulse air pressure
4840 ya³/h 63°F 1 " exible tube / 11,8in / 118in 96 Pa (N/m²)
TECHNICAL CHARACTERISTICS
Harmonized reference standards:
Apparatus compliant with safety standards:
CEI 61-150 (EN 60 335-1)
CEI 61-184 (EN 60 335-2-27)
And electromagnetic compatibility standards
CEI EN 55011, CEI EN 55014-2, CEI EN 61000-3-2, CEI EN 61000-3-3, CEI EN 61000-4-3.
Classi! cation for safety standards:
Fixed apparatus class I (for protection against electric shock), common type (for protection against humidity) (CEI 61-
150).
UV apparatus of type indicated in chart on page 13 (CEI 61-184).
Overall dimensions and weight of Solarium
Matrix L33-ER:
Tanning Machine Power supply
Electrical protection devices
Generated air:
Quality of expelled air
The expelled air is just heated room air, this air is not to be de# ned as treated or containing fumes of any kind since it is
not subjected to chemical processes or any other process.
Main parts of Tanning Machine:
Lamps types (see apparatus identi# cation on page 4).
Filters SICURPLEX + # lters UV type I.SO KL with serigraph
Circuit boards KEYPAD I.SO STP MEM = control board for general control
I.SO SPWR = power supply board
Emergency button (see instructions on page
14).
Main structure steel coated with epoxy powder paint
Finishing components made of polyurethane or methylmethacrylate, a material treated speci# cally to withstand
exposure to UV-A rays. Lamp
Protection Plexiglas made of transparent acridite (SICURPLEX) treated for UV-A rays.
Splitting system selector with key to turn on face section, body section or both
Medium loudnes 79 dB
Loudnes:
ONLY FOR INFORMATION
www.isoitalia.us