16
PROGRAMMING
VIEWING THE DISPLAY
USE OF CONTROLS, MEMORIZATION FUNCTIONS
AND PROGRAMMING FUNCTIONS
INITIAL PROCEDURE
When power is supplied to the panel, the central segments of the four LED displays will light up for a few
seconds. A test is then performed on all LEDs (displays and indicators) and ! nally the solarium is set to the
! rst memorized time with both face and body lamps selected.
To set the various parameters the solarium must be switched on, and the session, the various ventilation phases
and/or the raising of the motors must have been fully completed.
Reset procedure 1
With the button (C) pressed down and the solarium switched on, all memorized values are reset to the origi-
nal factory-programmed values. The display will show the message dEF for a few seconds, after which the
panel returns to default values.
Setting time 1
Press on succession buttons (B - A) to access program (time 1). The LED of button (C) will start to ! ash. It
is now possible to vary the memorized time with buttons (H-I).
Setting time 2
Push button (B) again to access program (time 2). The LED of button (D) will start to ! ash. It is now pos-
sible to vary the memorized time with buttons (H-I).
Setting time 3
Push button (B) again to access program (time 3). The LED of button (E) will start to ! ash. It is now pos-
sible to vary the memorized time with buttons (H-I).
End of programming phase
Press button (B) again to end the programming phase for the three times. Times can range from a minimum
of 1 minute to a maximum of 6 minutes. The factory-programmed times are 15, 10 and 5 minutes respec-
tively for times 1, 2 and 3.
When button (C) (program time 1) is pressed for 10 seconds, only time 1 will be activated.
Selection of the other two times is impeded. Repeat the operation to allow all three times to be selected again.
Display of number of times switched on
Press on succession buttons (B - I). The LED of button (C) will start to ! ash, and the display will show the
number of times the apparatus has been switched on (up to a maximum of 9999).
Key N°1 Modi! cation of the exposure times setting
Key N°2 Visualization of only one time of exposure on the display.
Key N°3 Reading of hours and n° of starts, accumulated hours ,
change of lamps and periodic maintenance
ONLY FOR INFORMATION
www.isoitalia.us