MAINTENANCE
CLEANING AND DISINFECTION
CAUTION!: THE OPERATOR MUST SWITCH OFF POWER FROM THE APPARATUS
BEFORE CLEANING AND/OR DISINFECTING THE MACHINE.
The ! lters must be cleaned periodically by the operator (about every 30 hours of operation) with water or glass detergent, after hav-
ing carefully followed the indications given by technicians trained and authorized by I.SO. Italia. During cleaning operations it is
essential to take the greatest care to avoid touching the lamps with the naked hands. If this does occur, clean the lamps touched
with a cloth soaked in denatured ethyl alcohol. Also take great care to avoid exchanging the ! lters, and ensure that ! lters are cor-
rectly repositioned, preventing white light from escaping.
The protective plexiglas panels of both the high-pressure lamps and the low pressure neon tubes, the synthetic leather upholstery
of the mattress or armchairs and the thermoformed plastic or polyurethane components of the tanning machine can be cleaned with
soap and water or speci! c products. Take care however to avoid the use of alcohol-based products.
CHECKING AND MAINTENANCE PROCEDURES
1
Every day the operator must check that cooling fans function correctly, that they expel air at a constant rate and that no
abnormal noises are produced.
2
Before every session the operator must check protection ! lters for possible damage, also ensuring that no white light
escapes in the direction of the lamps.In this case, switch off the machine at once and immediately contact the authorized
technician for the replacement of the broken ! lter.
3 The operator must warn the user not to obstruct ventilation grilles with objects and/or clothes.
4
At the end of the session the operator must allow the apparatus to complete the ventilation cycle for cooling of the lamps,
which lasts 3–6 minutes according to the model.The solarium is ! tted with a timer for residual ventilation. Should this
ventilation cycle fail to be activated, contact the technician authorized by I.SO. Italia S.p.A.
5
The operator must warn the user to touch neither the blue ! lters nor the lamps themselves with the naked hands.If contact
with the hands occurs, the ! lters and lamps must be carefully cleaned with a speci! c product or with alcohol, spraying it
onto a cloth and then wiping only the external surface of the lamp and of the blue ! lter.
6 The ! lters and protective glass panels can be cleaned with any glass detergent.
7
The plexiglas (SICURPLEX) panels giving external protection can be cleaned with speci! c products. They must NEVER
be cleaned with alcohol-based products.
8 Do not look directly at any type of white light given off by the apparatus or from one of its openings.
9
The operator (Caution"" Has the power supply to the apparatus been switched off ! rst?) must periodically lubricate and
grease the mechanical components that are part of the movement mechanisms for the backrest and face lamp units, using
lubricating oil or grease.The most important parts to be lubricated on the face lamp units are the sliding carriages and the
backrest hinges. Access can be easily obtained to these parts by removing protection covers and the base sections of seats.
The lubricating points on tanning beds are located mainly on the rotation shafts of the main movement mechanisms, where
to facilitate lubrication operations speci! c grease nipples have been ! tted. Access to these points is generally obtained by
removing the rear protection covers.
10
Check the air ! lters regularly so that air is able to # ow correctly to the turbines at all times, for cooling the lamps and for
the operation of the optional air conditioners.
11 Once a month control the functioning of the emergency button and the automatic return of the motors (where present)
12
Since various tan products’ combinings (oil, cream, etc.), that should be used during tanning sessions, where, in association
with UV rays, could cause unknown effects on the plexiglass and on the hal# eather, I.So Italia invites all costumer to use
protections everytime on the people support area:
- ! lm prepared for uv rays with plexiglass,
- paper roll or towel with hal# eather mattress.
IMPORTANT:
The requested periodic controls during the ! rst year of guaranty must be done every 500 hours of working time, or at least every
6 months. The periodic controls after the ! rst year are advised every 500 hours of working time or at least once a year.
For optimum yield of the of the apparatus, the UV-A ray emission should be measured by an authorized technician using a
speci! c instrument (at least every 300 hours of operation).It is advisable to replace the plexiglas every 400 hours of operation. If
impairment is noted earlier than this, check the correct operation of the ventilation system and the conditions of ! lters or glass
panels.It is advisable to replace the tanning lamps after about 400 hours of operation, and the neon tubes after about 600 hours
of operation, using only original replacements.These maintenance operations must be carried out by technicians trained and
authorized by I.SO Italia
ONLY FOR INFORMATION
www.isoitalia.us