!The!insertion!of!foreign!bodies!into!the!apparatus!through!cooling!slots!can!cause!malfunctions!and!create!
the!risk!of!electric!shock!and!"!res.
!Do!not!carry!out!any!type!of!technical!operation!on!the!apparatus!apart!from!the!operations!described!in!
this!manual.
!Pace-maker!wearers!must!take!particular!care,!as!the!apparatus!could!interfere!with!the!correct!operation!of!
the!pace-maker.
!Operation!in!the!vicinity!of!a!machine!for!short-wave!or!microwave!therapy!or!other!devices!that!generate!
signi"!cant!electromagnetic!interference!may!cause!malfunctions!in!electronic!components!of!the!appara-
tus,!also!jeopardising!the!health!of!the!user!being!treated.
!Do!not!replace!anti-interference!"!lters!with!non-original!spares!or!with!spares!not!supplied!by!I.SO!Italia,!
as!these!could!compromise!the!electromagnetic!compatibility!of!the!apparatus.
!Before!every!session!check!the!correct!operation!of!all!parts!and!functions!of!the!apparatus.
! Do not use the apparatus without protection • lters or with broken or non-original • lters.
!Changes!of!positions!on!the!sockets!of!lamp!ballasts,!intended!to!restore!the!nominal!power!output,!can!
be!made!only!every!200!hours!of!operation!of!the!UV!lamps;!this!operation!must!be!carried!out!only by
technicians trained and authorized!by!I.SO!Italia.
!UV!equipment!must!not!be!used!for!people!who!suffer!sunburn!without!becoming!tanned!when!exposed!to!
sunlight,!by!persons!who!suffer!from!solar!erythema,!by!children!and!by!persons!suffering!or!who!have!
previously!suffered!coetaneous!neoplasia!or!are!susceptible!to!this!disease.
-! The!functioning!of!the!buffer!batteries,!used!for!the!black-out!of!the!appliance,!is!to!be!checked!every!six!
months!and!its!replacement!is!advised!every!three!years;!when!they!have!to!be!disposed!of,!these!compo-
nents!are!to!be!considered!special!waste,!therefore!their!disposal!must!follow!the!established!regulations!
controlling!the!sector.
-! It!is!advisabe!to!verify!emergency!button!functioning!at!least!once!a!mounth.
-! When!they!have!to!be!disposed!of,!all!the!lamps!of!the!appliance!are!to!be!considered!special!waste,!there-
fore!their!disposal!must!follow!the!established!regulations!controlling!the!sector.
CAUTION:!At!the!end!of!every!daily!session!of!use!and!when!the!apparatus!is!left!unattended,!turn!off!the!
main!switch!to!disconnect!the!apparatus!from!the!mains!power!supply.
At!an!experimental!stage,!I.SO!Italia!has!adopted!further!safety!measures!(not prescribed by the regula-
tions in force),!regarding!radiation!hazards!from!high!pressure!lamps:
1.! for!the!new!generation!appliances!:!all!the!"!lters!are!"!tted!with!a!new!electronic!device!made!with!
an!electric!circuit!that!breaks!only!when!there!are!breaks!or!cracks.!Then!a!special!electronic!circuit!will!
automatically!stop!the!tanning!machine.
2.! for!all!the!other!types!of!appliance:!a!mechanical!micro-switch!is!positioned!in!contact!with!each!
"!lter!of!the!face!part.!This!switch!comes!into!action!only!after!complete!breaks.!Then!a!special!electronic!
circuit!will!automatically!stop!the!tanning!machine.
However,!since!the!break!can!occur!in!various!ways!(e.g.!only!in!limited!zones!or!with!imperceptible!
cracks,!etc.)!and!as!these!devices!are!still!at!the!experimental!stage,!there!is!no!absolute!certainty!of!their!
coming!into!action;!in!any!case!they!are!considered!only!as!a!back-up!to!the!checks!of!the!operators.
It is, in any event, always up to the operator to check, before each session, that the • lters are
perfectly intact and to switch off the appliance immediately if a break or crack, however slight,
in the • lter is found or if white light is passing, however small the amount. Also it is advisable to
inform the client of these problems and explain the most suitable conduct to follow.