GROUNDING INSTRUCTIONS 
The treadmill must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for 
electric current to reduce the risk of electric shock. The treadmill is equipped with a cord having an equipment-grounding 
conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded 
in accordance with all local codes and ordinances. If the user does not follow these grounding instructions, the user could void 
the Matrix limited warranty. 
ADDITIONAL ELECTRICAL INFO 
In addition to the dedicated circuit requirement, the proper gauge wire must be used from the circuit breaker box, to each 
outlet that will have the maximum number of units running off of it. If the distance from the circuit breaker box to each outlet, is 
100 ft (30.5 m) or less, then 12 gauge wire should be used. For distances greater than 100 ft (30.5 m) from the circuit breaker 
box to the outlet, a 10 gauge wire should be used.
ENERGY SAVING / LOW-POWER MODE
 
All units are configured with the ability to enter into an energy saving / low-power mode when the unit has not been in use for 
a specified period of time. Additional time may be required to fully reactivate this unit once it has entered the low-power mode. 
This energy saving feature may be enabled or disabled from within the ‘Manager Mode’ or ‘Engineering Mode.’
ADD-ON PCTV (T5X)  
A 15 A or 20 A “Dedicated Circuit” with a non-looped (isolated) neutral/ground is required.  Each PCTV requires at least 1.2 
A of current (at 110 V or 220 V). No more than 12 PCTVs should be used for each 15 A circuit and no more than 16 PCTVs 
should be used for each 20 A circuit. The power outlet should have the same configuration as the plug. No adapter should be 
used with this product. An RG6 coaxial cable with ‘F Type’ compression fittings will need to be connected between the video 
source and each add-on PCTV unit.
 
ADD-ON DIGITAL TV (T5X) 
Additional power requirements are not needed for the add-on digital TV. An RG6 coaxial cable with ‘F Type’ compression 
fittings will need to be connected between the video source and each add-on digital TV unit.
7