MAULE AEROSPACE TECHNOLOGY, INC.
AIRPLANE FLIGHT MANUAL
MAULE MX-7-180B
SECTION II
LIMITATIONS
2.2 POWER PLANT LIMITS:
Engine: Lycoming O-360-C1F
Engine Limits: 180 hp @ 2700 rpm, Full Throttle Continuous
Propeller: Hartzell Constant Speed HC-C2YR-1BF/F7666A (76")
Fuel: 100/100LL Minimum Grade Aviation Gasoline
Engine Instrument Markings:
Cylinder Head Temperature: Green Arc - Normal Operating Range,
200°F - 435°F
Red Radial -
Operating Limit, 500°F
Oil Temperature: Green Arc - Normal Operating Range,
140°F - 245°F
Red Radial -
Operating Limit, 245°F
Oil Pressure: Green Arc - Normal Operating Range,
55 to 95 PSI
Yellow Arc - Caution Range, 25 to 55 PSI
and 95 to 115 PSI
Red Radial - Minimum Operating Pressure,
25 PSI
Red Radial - Maximum Operating Pressure,
115 PSI
Fuel Pressure Green Arc - Normal Operating Range,
0.5 to 8 PSI
Red Radial - Minimum Pressure, 0.5 PSI,
Red Radial - Maximum Pressure, 8.0 PSI
Tachometer: Green Arc -
Normal Operating Range,
2250 - 2600 RPM
Red Radial - Maximum RPM, 2700 RPM
Red Arc - Avoid Continuous Operation,
2000 - 2250 RPM
FAA APPROVED
DATE: 7/12/93 PAGE 4