9. OPERATION LIMITS
Cooling operation Heating operation Drying operation
Room temperature 17°C ~ 32°C 0°C ~ 30°C 17°C ~ 32°C
Outdoor temperature
0°C ~ 50°C
-15°C ~ 24°C 0°C ~ 50°C
(-15°C ~ 50°C
:
For the models with low
temperature cooling system)
1. For proper performance, operate the unit under the usable operating temperature and humidity conditions indicated
in this manual. If the unit is operated beyond these conditions, it may cause malfunctions of the unit or dew dripping
from the unit.
2. The phenomenon is normal that the surface of air conditioning may condense water when the relative larger
humidity in room (>80%), please close the door and window.
3. Optimum performance will be achieved within the operating temperature range.
Note: It is advisable to use the units within the indicated temperature ranges in order to avoid malfunctions of the
system.
10. INSTALLATION
10.1 Dimentions
Before starting the installation of the system, please decide with the customer where the unit is to be installed, whilst
paying attention to the following:
- The support surface must be capable of supporting the unit weight.
- The safety distances between the units and other appliances or structures must be scrupulously respected.
- The unit must be installed by a qualified technician in compliance with national laws in the country of destination.
- It is necessary to include the rewquired minimum technical spaces in order to allow routine and extraordinary
maintenance interventions.
- Fix the unit checking that it is level.
Models (W)
800 333 554 870 514 340
946 410 810 1030 673 403
23