Fusing charging station
Maxemisacontrolsystemthatregulatestheloadofthechargingstation.Maxemmakes
surethatthereislessloadonthechargingstationwhenthereismoreloadonthehouse.
This reduces the diversity factor. The charging station can thereforebe fusedto a value
higherthannormal,butnothigherthanthethresholdvalueofthemaingridconnection.
FormoreinformationonthissubjectinrelationtotheNEN1010,seetheMaxemwebsite.
Power supply Charging station capacity Maximal fusing, charging station
3-phase 25A 3-phase 32A 3-phase 25A
3-phase 25A 3-phase 16A 3-phase 16A
3-phase 35A 3-phase 32A 3-phase 32A
1-phase 25A 1-phase 32A 1-phase 25A
1-phase 40A 1-phase 32A 1-phase 32A
Current transformers of kWh-meters
Maxem is standard supplied with current transformers with which the main grid connection
andsolarproductioncanbemeasured.Formoreaccuratemeasurementsitisalsopossible
to use MID certied kWh-meters. The kWh-meters Maxem works with can be ordered
separately.
There are situations when a kWh-meter is always required:
• Measurement of a Tesla Wall Connector
• Measurement of a heat pump