36
01 02
01 02
Error Detection
For any additional troubleshooting help, please contact Support@maxfoot.bike.
#21-Abnormal Current: Check if the phase of motor is short circuiting.
#22-Abnormal Throttle: Check whether the throttle is functioning properly.
#23-No Phase State: Check if the phase wire is normal or check if the cable is firmly connected
with controllers.
#24-Abnormal Hall Signal: For controller without hall sensors, check if the phase wire is normal; for
controller with hall sensors, check if the hall wire is normal.
#25-Abnormal Brake: The brake may be too tight, or the cables connected to the brake are broken.
#30-Abnormal Communication: Check if the cables are properly connected to each part.