1. Unchain Liftgate by un-
hooking snap hook from
tilt arm (FIG. 16-1).
2. Hold the external up-down
toggle switch in the DOWN
position (FIG. 16-2) until
lowest point of platform
and arms are 6” above the
ground (FIG. 16-3).
DOWN SWITCH
FIG. 16-2
NOTE: If necessary, release the
toggle switch to stop the
platform from moving.
OPERATION
UP-DOWN
TOGGLE SWITCH
LOWEST POINT 6” ABOVE GROUND
FIG. 16-3
Damage will occur if Liftgate
is not in correct position when
operating the slide function.
Ensure platform & arms have
6” of ground clearance, at low-
est point, before Liftgate is run
out from under vehicle.
CAUTION
CAUTION
!
Ensure Liftgate is unchained before you deploy Liftgate for
operation. Possible injury and equipment damage could result.
CHAIN
SNAP HOOK
UNCHAINING LIFTGATE
FIG. 16-1
TILT ARM
6”