Extended AT Commands Manual Page 19 of 70 2009-06-25
Table 5-14 Read command
Command TE2
Æ
MT2 $$EMMOREG?
Response TE2
Å
MT2 $$EMMOREG: period,terminatednumber,TI,msg
Value
period: 5 – 300 (seconds)
terminatednumber: mobile number
TI: Teleservice Identifier (4098)
msg: User data
Table 5-15 Set command
Command TE2
Æ
MT2 $$EMMOREG=<period,terminatednumber,TI,msg>
Command TE2
Æ
MT2
$$EMMOREG=CANCEL (Disable – No $$TE2ALIVE
command expected by MT2)
Response TE2
Å
MT2 $$EMMOREG: 1 | 0 (Success | Failure)
5.1.1.4. TE2 active command (AT$$TE2ALIVE)
If $$EMMOREG command has been enabled in MT2 then TE2 must transmit $$TE2ALIVE
command to MT2 within the time frame value specified in the $$EMMOREG command.
Table 5-16
Command TE2
Æ
MT2 $$TE2ALIVE
Response TE2
Å
MT2 <result_code> (OK | ERROR)
5.1.1.5. Power Reset (AT$$RESET)
Command to reset Modem, which is utilised to perform an immediate or scheduled soft power-
off/on cycle.
Table 5-17 Read command
Command TE2
Æ
MT2 $$RESET?
Response TE2
Å
MT2 $$RESET: <value>, <on/off>
Value time: 0~12960000 (minutes) (0: Periodic Power Reset Disabled - Default)
On/off
0: will execute time only in idle state, IPStack in listening state connecting
using $$IPCTOS command not the $$CNS command
1: will execute timer in all states
Table 5-18 Set command (scheduled reset)
Command TE2
Æ
MT2 $$RESET=<value>,<on/off>
Response TE2
Å
MT2
$$RESET: <time>, <on/off>
<result_code> (OK | ERROR)
Table 5-19 Execute command (performs immediate reset)