EasyManua.ls Logo

Maxon MODMAX MM-6280IND - Basic at Commands; Basic at Parameters

Maxon MODMAX MM-6280IND
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Extended AT Commands Manual Page 56 of 70 2009-06-25
12.2. Basic AT Commands
The following table specifies the basic AT parameters to be supported for the data service.
Exceptions to EIA/TIA-602 are indicated by square brackets. Default settings are shown in bold.
12.2.1. Basic AT Parameters
Table 12.78 Basic AT parameters
Parameter Description
Packet
Data
STU-
III
E0
Do not echo command set in command state or online
command state.
O N/A
E1
Echo command set in command state or online command
state.
O N/A
L0 Low speaker volume. N/A N/A
L1 Low speaker volume. N/A N/A
L2 Med speaker volume. N/A N/A
L3 High speaker volume. N/A N/A
M0 Speaker off. N/A N/A
M1
Speaker on until carrier reported (support of this feature is
optional).
N/A N/A
Q0 Return result codes. R R
Q1 Do not return result codes. R N/A
V0 Display result codes as numbers. R R
V1 Display result codes as words. R R
X1
Enable additional result code CONNECT <rate>. Disable dial
tone and busy detection.
1
N/A N/A
X2
Enable additional result codes CONNECT <rate> and NO
DIALTONE. Disable busy detection. Enable dial tone
detection.
1
N/A N/A
X3
Enable additional result codes CONNECT <rate> and BUSY.
Enable busy detection. Disable dial tone detection.
1
N/A N/A
X4
Enable additional result codes CONNECT <rate>, BUSY
and NO DIALTONE. Enable busy and dial tone detection.
1
N/A N/A
Z0
Reset to default user configuration.
Note: ATZ with firmware R2.1.3 clears the +CSCA
settings. You have to enter the +CSCA values again to be
able to send SMS messages.
R N/A
&C0
Circuit 109 (CF) always ON.
R N/A

Table of Contents