11921 Slauson Ave.  Santa Fe Springs, CA.  90670  (800) 227-4116  FAX (888) 771-7713
17
3.  Lower the platform all the way to the ground      
   while draining the remaining hydraulic fl uid. 
5. Pull out (no threads) fi ller cap (FIG. 16-2).  
 Add 1 gallon of hydraulic fl uid to reservoir.
    Re-install fi ller cap.
CAUTION
Pump cover must be correctly se-
cured to prevent it from becoming 
a hazard. To secure pump cover, 
the long side of the holder fl ats 
must butt against pump cover as 
shown in the illustration.
7. Bolt on the pump cover as shown 
in FIG. 17-1. Torque the 5/16”-18 
cover bolts from 10 to 14 lb-in. 
6. Stow the Lift and do the CHECKING 
HYDRAULIC FLUID procedure in this 
section of the manual.
BOLTING ON PUMP COVER
FIG. 17-1
4.  Reinstall drain plug (FIG. 16-2).  
CAP SCREW, 
5/16”-18
(2 PLACES)
HOLDER FLAT
(2 PLACES)
FLAT WASHER,
 5/16”
(2 PLACES)
NYLON NUT,
 5/16”-18 
(2 PLACES)
PUMP COVER
POWER UNIT
(REF)