11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
16
CHANGING HYDRAULIC FLUID
CAUTION
Keep dirt, water and other contaminants from entering the hydraulic system.
Before opening the hydraulic fl uid reservoir fi ller cap, drain plug and hydrau-
lic lines, clean up contaminants that can get in the openings. Also, protect the
openings from accidental contamination.
+50 to +120 Degrees F - Grade ISO 32
Below + 70 Degrees F - Grade ISO 15 or MIL-H-5606
NOTE: Use correct grade of hydraulic fl uid for your location.
See TABLES 15-1 & 15-2 for recommended brands.
1. Unbolt and remove pump cover
(FIG. 16-1). Place empty 5
gallon bucket under drain plug
(FIG. 16-2).
2. Open and raise platform to vehicle bed
height. Pull out (no threads) drain plug
(FIG. 16-2). Drain hydraulic fl uid.
UNBOLTING PUMP COVER
FIG. 16-1
POWER UNIT
FIG. 16-2
DRAIN PLUG
PERIODIC MAINTENANCE
FILLER CAP
CAP SCREW,
5/16”-18
(2 PLACES)
HOLDER FLAT
(2 PLACES)
FLAT WASHER,
5/16”
(2 PLACES)
NYLON NUT,
5/16”-18
(2 PLACES)
PUMP COVER
POWER UNIT