Tip: The remote control supplied with the
generator has been paired successfully.
OPERATION
STOPPING THE INVERTER
Normal Operation
During normal operation, use the following steps
to stop your inverter:
1. Remove all the loads out of the output.
2. Press "START UP" Button to stop the generator.
3. Turn the LPG/GAS switch to middle to turn off
the fuel.
During an Emergency
To stop the engine in an emergency, please
directly press "START UP to stop the generator.
USING EFFICIENCY MODE
The inverter is equipped with an efficiency mode
switch to minimize fuel consumption. In efficiency
mode, the inverter will sense the load and adjust
the engine RPM to the current load requirements.
Efficiency mode should be used only after the
inverter has been warmed up to operating
temperature.
1. To turn on the efficiency mode, press the switch
to the ON position).
2. If no load is present, the inverter RPM will drop
down to an idle speed.
3. As a load is applied, the inverter will sense the
load and engine RPM will increase according to
the load applied.
4. To run the inverter at maximum power and RPM,
press the efficiency mode switch to the OFF
position.
RESETTING THE RESET BREAKER
The inverter will trip the breaker and automatically
disconnect from the load when the controls sense a
predetermined overload condition. The inverter
engine will continue to run, but there will not be any
electrical output.
1. Turn off all devices and unplug them from the
inverter.
2. Determine the wattage required from the devices
being powered by the inverter Make sure the
wattage required does not exceed the maximum
output of the inverter.
3. Press in the reset breaker to reset it (see Figure 13).
Figure 13: Press in reset breaker
4. Plug the devices in to the inverter.
5. Turn on the devices as needed.
15
MAXPEEDINGRODS
DIGITAL DISPLAY CENTER
HOURS
GASOLINE FUEL METER FREQUENCY
POWER
START UP
USB
REST
PARALLEL
AC 120V 30A
NEUTRAL BONDED TO FRAME
AC 120V 20A
NEUTRAL BONDED TO FRAME
PUSH TO
SYSTEM BONDED TO FRAME
LOW IDLE
MAINTENANCE
REQUIRED SEE
MANUAL
CARBON
MONOXIDE
DETECTED
This generator
comes equipped with
CO ALERT, advanced
technology to prevent
death or injury from
carbon monoxide
poisoning.
DO NOT CONNECT OR
DISCONNECT PARALLEL
CABLES WHILE UNIT IS
RUNNING TO AVOID
DAMAGE.
20A
ON UN
OFF/R ET
NO OFF
OVERLOAD LOW OIL
VOLTAGE LOAD
CO ALERT
!
CAUTION
6
4
2
3
8
11
1
9
10
5
ENGINE
START
STOP
Figure 11
(3)Remote Start: Push and hold the ON button
on the remote start key fob for one second.
Key Fob
Activation Light
START Button
STOP Button
START
STOP
Figure 12
DANGER
Fire and explosion hazard. Always turn the propane
tank valve to the fully closed position if not running the
generator on propane.
WARNING
WHEN USING THE GENERATOR WITH LPG MAKESURE
THERE IS NO POSSIBLE IGNITION SOURCECLOSE TO THE
GENERATOR
1. Before using, make sure all of the LPG connectors
and hoses are well connected and sealed.
2. Connect electrical devices to the generator ONLY
after the engine runs smoothly. (There may be
remnant gasoline in the carburetor; this can cause
unsteady engine performance for several minutes).
3. If the propane gas leaks, shut off the LPG supply first
and then quickly unplug or turn off any electrical
devices powered by the unit.
Remote Control Pairing
1. Press the "START UP" button for 5 seconds, release
it when the "START/MATCH" indicator lights up.
2. Before the "START UP" indicator light goes out,
press "ON" on the remote control for 1 second, the
"START/MATCH" indicator light goes out, this time
the generator set starts.
3. Press "OFF" on the remote control for 1 second. the
generator set shuts down, the remote control is
paired successfully.