'SELF CLEANING FILTER'
MANUAL
'SELF CLEANING FILTER' FUNCTION
With switch (B) in position “I”, when
switch (A) is set to the “AUTOMATIC”
position the Self Cleaning lter function
is activated.
When the appliance is switched off, it
will continue to run for 8/10 seconds,
then the self-cleaning lter function will
begin.
When the switch 'A' is set
to MANUAL the Self Cleaning
Filter function is not active.
If the air speed drops to below 20 m/sec., the warning light comes
on (in accordance with IEC/EN 60335-2-69)
O
C
B
A
Warning light (C) on:
manually start the “Self-cleaning lter”
function; press the orange switch (E).
For proper cleaning of the lter element,
follow the instructions on page 26
Continuous operation of the “Self-cleaning lter” system for more than 60
seconds may cause the thermal protection switch to trip.
FOR USE WITH POWER
TOOL
Selector switch (A): in “AUTOMATIC”
position.
Power switch (B): position “I” -
Appliance on.
The appliance runs in sync with the
power tool.
POWER TOOLS
C
B
A