Crusader
MC-8
[ "°' 16-34
HIGH
LOW
PRESSURE
SWITCH
The.
Hi-Lo
pressure
cut-out
switch
prevents
the
operat10n
of
the
system
when
refrigerant
pressures
are
above
or
below
preset
limits.
When
pressures
exceed
the
limits,
the
switch
in-
terrupts
the
loading
solenoid
circuit
and
unloads
compressor.
Low
pressure
cut-out
and
cut-in
limits
are
adjustable;
high
pressure
cut-out
limit
is
ad-
Justable,
but
the
cut-in
limit
is
fixed
and
non-
adjustable.
B A
C
Figure 16-47: Hi-Low Pressure Switch
Mounted
in front
of
A/C
Compressor
TESTING
HI-LO
PRESSURE
SWITCH
I)
Connect
test
light
to
stud
No.
4
on
junction
block
to
check
Hi-Lo
pressure
switch.
2)
Install
service
gauges
at
the
compressor
suction
and
discharge
shut-off
valves.
3)
Operate
the
air
conditioning
allowing
the
system
to
stabilize.
(Approx.
IO
min.)
Low
Pressure:
Close
suction
valve
slowly,
noting
the
pressure
when
the
light
goes
out
(4-6
psi.).
Open
valve
slowly
and
note
when
light
goes
on
(35-38
psi.).
High
Pressure:
Open
condenser
door
and
cover
condenser
core
if
necessary
in
order
to
raise
the
high
pressure.
Note
the
pressure
when
the
light
goes
out
(275
psi.).
Close
the
condenser
door
and
note
pressure
when
the
light
goes
on
(approx.
220)
(psi.
not
adjustable).
ADJUSTMENT
To
make
adjustments;
remove
control
cover
to
per-
mit
viewing
direct
reading
scale
plates.
Gasketed
MAINTENANCE
DA
rE
~Ju:.c_J__I
y_L_,
--'-19~73~-l
MANUAL
screws
m
control
case
can
be
removed
for
screwdriver
adjustment
or
adjustment
can
be
made
with
a
service
wrench
without
removing
gasketed
screws.
Set
adjusting
screw
"A"
(Fig.
16-47)
at
5 lbs.
for
the
low
pressure
cut-out
limit.
Set
adjusting
screw
"B"
at
38
lbs.
for
the
low
pressure
cut-in
limit.
(Tolerances
± 3
lbs.)
Set
high
pressure
cut-out
screw
"C"
at
275
lbs.
The
high
pressure
cut-in
differential
is
factory-set
at
ap-
proximately
55
lbs.
below
cut-out
pressure.
For
refrigerant
500
the
hi-low
pressure
switch
cut
out
should
be
set
at
325
psi.
The
cut-in
setting
should
be
55
psi.
below
325
psi.
CAPACITY
CONTROL
SWITCH
A
capacity
control
switch
is
mounted
on
one
bracket
to
the
front
of
the
A/C
compressor
mount
and
is
connected
electrically
in
the
"Loading
Circuit''
and
operates
a
loading
solenoid
which
controls
the
operation
of
one
cylinder
of
the
compressor.
The
capacity
control
switch
sense
suction
pressure
and
unloads
one
cylinder
when
the
suction
pressure
falls
to
27
psi.
to
reduce
refrigeration
capacity
and
driven
horsepower
load
during
moderate
to
light
air
con-
ditioning
requirements.
TESTING
CAPACITY
CONTROL
SWITCH
I)
To
check
capacity
control
switch
connect
test
light
to
terminal
M-2
of
that
switch.
2)
Close
suction
valve
slowly
noting
pressure
when
test
light
goes
out.
(26-28
psi.)
8 A
Figure
16-48:
Capacity
Control
Switch
Mounted
in
front
of
A/C
Compressor