Self-contained Air Conditioning System
Type SWP Vintage Sizes 18D thru 95D, 105E
Installation and Maintenance IM-708
Group: Applied Systems
Part Number: IM708
Date: February 2002
MEA
368-93-E

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the McQuay SWP 095 and is the answer not in the manual?

McQuay SWP 095 Specifications

General IconGeneral
BrandMcQuay
ModelSWP 095
CategoryAir Conditioner
LanguageEnglish

Summary

Introduction and Unit Overview

Equipment Inspection Upon Receipt

Instructions for carefully checking received equipment for completeness and damage.

Installation Procedures and Guidelines

Safe Unit Handling and Movement

Provides guidelines for safely moving and handling the unit during installation.

Location and Service Access Requirements

Specifies recommended clearances for unit installation and maintenance access.

Refrigerant Piping and Pressure Relief

Pressure Relief Valve Specifications

Describes the spring-loaded relief valve setpoint and venting connection.

Field Wiring and Electrical Connections

General Field Wiring Requirements

Covers wiring compliance, safety, and component identification.

Supply Power Wiring and Lug Sizing

Control Center Layout and Components

Typical Wiring Schematics

Power Schematic Diagram

Illustrates the main power wiring for the unit circuits.

Input Schematic: Discharge Air Control (DAC)

Input Schematic: ZoneSpace Comfort Control (SCC)

Output Schematic: Actuator Control

Output Schematic: Actuator Control Details

Output Schematic: Auxiliary Fan Control

Output Schematic: Compressor Control (4 Compressors)

Output Schematic: Compressor Control (6 Compressors)

Standard Unit Control Features

High Pressure Switch Operation

Explains the function and setpoints of high pressure switches.

Low Pressure Switch Operation

Describes the function and setpoints of low pressure switches.

Compressor Motor Protector Function

Details the thermal protection for compressor motors.

Proof of Airflow Switch Function

Explains the airflow switch for fan operation monitoring.

Frost Protection Switch Function

Describes the switch that protects against evaporator coil freeze-up.

System Check, Test, and Start Procedures

Unit Operation Start-up Sequences

Refrigerant Charge and Superheat Adjustment

Drive Sheave Alignment and Belt Tension

Final Control Settings Configuration

Service and Warranty Procedures