EasyManua.ls Logo

MCZ BOXTHERM 70 AIR 9 BASIC M1 - Panel Functions and Information

MCZ BOXTHERM 70 AIR 9 BASIC M1
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
20-EMERGENCY PANEL FUNCTIONS
The emergency panel provides the following information:
• through a multicolour LED (A) it provides information about the stove status (o-starting-up-in operation-cooling for shutdown- in
error conditions)
• using the button (B) the following functions can be activated:
• if the product triggered an error ----- reset the error by pressing the key for more than 3 seconds
Attention! Alarms A01, A02, A03, A05 and A21 can only be reset from the panel and not from the app.
• if the product is o ------- switch it on (press the key for more than 3 seconds)
• if the product has completed the ignition procedure (green LED on), press the key (briey for 0.5 seconds) to change the power
according to this diagram:
• LOW ame power 1 and ventilation level 1
• MEDIUM ame power 3 and ventilation level 3
• HIGH ame power 5 and ventilation level 5
Every time the power is changed, a buzzer will indicate the selected power on the stove:
• 1 beep LOW
• 3 beeps MEDIUM
• 5 beeps HIGH
If the product is running, switch it o by pressing the key for 3 seconds.
Attention! If the user erroneously presses the button for more than 10 seconds with the stove o, this will
automatically place the stove in download mode to update the rmware (operation restricted to an authorised
technician). This way, the stove remains in standby, with an intermittent buzzer, for a USB key containing the
rmware update. If a USB key is not inserted, the stove exits this mode after 10 seconds.