14
20-EMERGENCY PANEL FUNCTIONS
The emergency panel provides the following information:
• through a multicolour LED (A) it provides information about the stove status (o-starting-up-in operation-cooling for shutdown- in
error conditions)
• using the button (B) the following functions can be activated:
• if the product triggered an error ----- reset the error by pressing the key for more than 3 seconds
Attention! Alarms A01, A02, A03, A05 and A21 can only be reset from the panel and not from the app.
• if the product is o ------- switch it on (press the key for more than 3 seconds)
• if the product has completed the ignition procedure (green LED on), press the key (briey for 0.5 seconds) to change the power
according to this diagram:
• LOW ame power 1 and ventilation level 1
• MEDIUM ame power 3 and ventilation level 3
• HIGH ame power 5 and ventilation level 5
Every time the power is changed, a buzzer will indicate the selected power on the stove:
• 1 beep LOW
• 3 beeps MEDIUM
• 5 beeps HIGH
If the product is running, switch it o by pressing the key for 3 seconds.
Attention! If the user erroneously presses the button for more than 10 seconds with the stove o, this will
automatically place the stove in download mode to update the rmware (operation restricted to an authorised
technician). This way, the stove remains in standby, with an intermittent buzzer, for a USB key containing the
rmware update. If a USB key is not inserted, the stove exits this mode after 10 seconds.