Me2, Fog Generator
Operating Guide, Rev: A/a 19 / 30
The RDM supported parameters implemented in the MDG Me2 Fog Generator are summarized
in the following table.
RDM Parameter ID’s
Value
GET
Allowed
SET
Allowed
Comments
DISC_UNIQUE_BRANCH
0x0001
DISC_MUTE
0x0002
DISC_UN_MUTE
0x0003
QUEUED_MESSAGE
0x0020
STATUS_MESSAGES
0x0030
SUPPORTED_PARAMETERS
0x0050
PARAMETER_DESCRIPTION
0x0051
DEVICE_INFO
0x0060
PRODUCT_DETAIL_ID_LIST
0x0070
DEVICE_MODEL_DESCRIPTION
0x0080
White Mineral oil hazer
MANUFACTURER_LABEL
0x0081
MDG Fog Generators Ltd
DEVICE_LABEL
0x0082
SOFTWARE_VERSION_LABEL
0x00C0
DMX_PERSONALITY
0x00E0
1
DMX_PERSONALITY_DESCRIPTION
0x00E1
DMX_START_ADDRESS
0x00F0
1 to 510
SLOT_INFO
0x0120
SLOT_DESCRIPTION
0x0121
DEFAULT_SLOT_VALUE
0x0122
IDENTIFY_DEVICE
0x1000
LCD flashes
MDG_GENERATOR_STATE
0x8002
ASCII text
(Up to 20 characters)
MDG_LCD_SAVER
0x8004
Unsigned Byte
(0=30 s,1=2 min, 2=Off)
MDG_COM
0x8005
Unsigned Byte
(0=AUTO,1=LOCAL, 2=DMX)
Table 1: RDM Supported Parameters.