13
8 Bar Pressure Relief Valve (See Figure 5)
This should be installed between the 3 bar Pressure Reducing Valve and the Megaflo eco cylinder. S

Branches to drinking water outlets should be taken before the 8 Bar Pressure Relief Valve to avoid the possibility of warm
expanded water being drawn from the tap.
Figure 5 - 8 Bar Pressure Relief Valve
Figure 6 - Valve set can be grouped two ways
22mm compression connection
Outlet to Megaflo
From cold water
Combination Valve
Take note of flow
direction
Pressure Relief Valve
discharge connection
Pressure Relief Valve
TEE” ( incorporates
Check Valve )
Stopcock can be grouped with either
3 Bar Pressure Reducing Valve or
8 Bar Pressure Relief valve on the
inlet to either valve only
8 Bar Pressure Relief
Valve
3 Bar Pressure
Reducing Valve
Stopcock

