MENDOTA
GAS DIRECT VENT FIREPLACE
Model DXV-45
SHOWN WITH OPTIONAL PRAIRIE DOOR KIT AND OVERLAY
INSTALLATION & OPERATING INSTRUCTIONS
NO. 1002
WARNING: DO NOT OPERATE THIS APPLIANCE WITH THE GLASS
REMOVED, CRACKED OF BROKEN. REPLACEMENT OF GLASS
SHOULD BE DONE BY A
LICENSED OR QUALIFIED PERSON.
WARNING: This product must be installed by a licensed plumber or gas fitter when installed in the commonwealth of Massachusetts. Improper installa-
tion, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information
consult a qualified installer, service agency or the gas supplier.
FOR YOUR SAFETY:
IF YOU SMELL GAS:
1. OPEN WINDOWS.
2. DO NOT TOUCH ELECTRICAL SWITCHES.
3. DO NOT TRY TO LIGHT ANY APPLIANCE.
4. EXTINGUISH ANY OPEN FLAME
5. DO NOT USE THE PHONE IN YOUR BUILDING.
6. IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S
PHONE.
7. FOLLOW THE GAS SUPPLIERS INSTRUCTIONS.
8. IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE
DEPARTMENT.
FOR YOUR SAFETY
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED
INSTALLER, SERVICE AGENCY, OR THE GAS SUPPLIER. DO NOT STORE
OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE
WARNING: MENDOTA GAS FIREPLACES ARE HEAT PRODUCING
APPLIANCES. DO NOT BURN WOOD, PAPER OR OTHER
MATERIALS IN THE FIREPLACE. THE FIREPLACE IS
DESIGNED AS A SUPPLEMENTAL HEAT SOURCE. IT IS
ADVISABLE TO HAVE AN ALTERNATE HEAT SUPPLY.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER!

Questions and Answers

  • J
    Jeremy DavisAug 1, 2025
    What to do if I see a change in flame appearance in my Mendota DXV-45 Indoor Fireplace?
    • M
      mcgeepaulaAug 1, 2025
      If you observe a change in the flame appearance or burner operation of your Mendota Indoor Fireplace, it could be due to a change in gas pressure or the presence of carbon dirt or lint. First, have your gas supplier check the gas pressure (7" W.C. for Natural Gas; 11" W.C. for LP Gas). Also, clean out any carbon, spider webs, or lint from the shutter area, logs, and burner. Ensure that you never block the air intake or outlet vents.
  • D
    Deborah WuAug 8, 2025
    How to remove soot from Mendota DXV-45 Indoor Fireplace glass?
    • A
      Andrew FloresAug 8, 2025
      If a thin black coating (soot) forms on the viewing glass of your Mendota Indoor Fireplace, it could be due to incorrect gas pressure or insufficient combustion air. Have your gas supplier check the gas pressure (7" W.C. for Natural Gas; 11" W.C. for LP Gas). If sooting continues, open the air shutter on the burner. If the issue persists, shut off the unit and call a Mendota service person. To clean the glass, remove it and wipe it with a cloth or paper towel.
  • K
    Kimberly GayAug 15, 2025
    Why is my Mendota Indoor Fireplace humming?
    • B
      Brittany PowellAug 15, 2025
      Some humming or whistling from your Mendota Indoor Fireplace is normal due to the gas supply flowing through the gas orifice. This is expected from any gas fireplace. You can reduce the noise and the heat output by turning the Hi/Lo Knob on the control to turn down the flame.
  • S
    Stephen SingletonAug 25, 2025
    Why is there a change in flame appearance in my Mendota Indoor Fireplace?
    • S
      stewartmaryAug 25, 2025
      A change in flame appearance or burner operation in your Mendota Indoor Fireplace can be caused by a change in gas pressure. Have your gas supplier check for the correct gas pressure (7" W.C. Nat. Gas; 11" W.C. LP Gas). It can also be caused by carbon dirt or lint. Clean out any carbon, spider webs, lint, etc. from the shutter area, logs, and burner. Never block air intake or outlet vents.

Summary

Specifications

Safety and Structural Concerns

Specifications & Clearances

Installation Instructions

Gas Supply Requirements

Gas Pressure Requirements

Exterior Vent Locations and Restrictions

Flue Venting Instructions

Flue Venting Requirements

Minimum Rise Through-the-Wall Venting

Elevated Rise Through-the-Wall Venting

Vertical Through-the-Roof Venting

Coal Bed and Logs Installation

Installation Check Off List

Lighting Check Off List

Lighting Instructions

Thermostat or Remote Control Operation

Mendota Blower & Burner Removal & Installation

Troubleshooting Mendota Gas DXV Fireplace

Main Burner Gas Flame Adjustment

Procedure for adjusting the air shutter for optimal flame appearance.

Maintenance

Combustion System Millivolt Reading

Procedures for checking millivolt readings for pilot and main burner operation.

Listed Direct Vent Gas Fireplace Heater

Minimum Clearances to Combustible Construction

Required clearances to combustible materials for installation.

Warranty Registration

And Limited Warranty

Extended Lifetime Warranty

Lifetime warranty on specific components with conditions.

Mendota DXV-45 Specifications

General IconGeneral
TypeDirect Vent Gas Fireplace
Fuel TypeNatural Gas or Propane
BTU/hr Input45, 000
Heating Capacity1, 500 sq. ft.
Vent TypeDirect Vent
Ignition SystemElectronic Ignition