MAINTENANCE
69
IMPORTANT: Never run the engine without the compressor air
intake filter.
REMOVAL
1. Open the clamp and lift out the filter housing. Rotate the filter
housing 1/4 turn clockwise to the unlock position and remove
the air filter.
2. Remove the hose cable tie and and pull the air filter off the
hose.
a
b
c
28732
d
e
f
a - Air filter
b - Nylon washer
c - Rubber washer
d - Clamp
e - Filter housing
f - Cable tie