Page 6 Microcook HD Ovens 32Z3385 Issue 5
Installation instructions
Power Supply Requirements
The Microcook HD & Microcook TA ovens should be connected to a suitable electricity
supply, which can cope with the switching-on surge that occurs with certain types of
catering equipment, such as microwaves. Because of this requirement, we strongly
recommend that a separate, suitably rated supply is installed for the oven.
The supply for the oven should be fitted with a Type "C" circuit breaker, rated at 16A.
Positioning the Oven
In order to maintain adequate ventilation for air intake and exhaust, and to allow access
for cleaning filters, you must allow a minimum of 50mm clearance all around the oven. Air
intake temperature should not exceed 35°C - excessive temperature can lead to reduced
operating duty cycle or premature ageing of internal components.
NEVER Install an oven above fryers, grills, griddles or any other major heat
source.
NEVER Stack machines on top of each other
ALWAYS Place containers in the cavity carefully - impact damage may chip the
oven shelf.
Note:
The 840mm clearance at the front allows the
complete removal of the door for cleaning
A – HD2025 Model
B – HD1025 Model