EasyManuals Logo

Meru Networks AP200 User Manual

Default Icon
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
Install the AP300
© 2010 Meru Networks, Inc. Installing AP300 31
Figure 11: AP300 Mounted Above a Suspended Ceiling Face Up
The AP300 with the metal enclosure exposed meets the requirements for fire resistance and low
smoke-generating characteristics required by Section 300-22(C) of the National Electrical Code (NEC)
for installation in a building’s environmental air space.
You may need to modify thicker tiles to support this installation.
Warning!
When installed in air-handling spaces, such as above a suspended ceiling,
power the AP300 only with a PoE, not a power supply. See Power Supplies for part
numbers.
Warning!
Any Fast Ethernet (FE) cables installed in air-handling spaces should be
suitable under NEC Article 800.50 and marked accordingly for use in plenums and air-
handling spaces with regard to smoke propagation, such as CL2-P, CL3-P, MPP (Multi
Purpose Plenum), or CMP (Communications Plenum). Use Ethernet cable that meets
the requirements for operating in plenums and environmental air space in
accordance with Section 300-22(C) of the NEC.
00232

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Meru Networks AP200 and is the answer not in the manual?

Meru Networks AP200 Specifications

General IconGeneral
BrandMeru Networks
ModelAP200
CategoryWireless Access Point
LanguageEnglish

Related product manuals