Power supply .......................................................................................................12Vcc (10V-15V)
Consumption .........................................................................................................................1,0 mA
Consumption in DEEP SLEEP MODE ............................................................................. 0,3 mA
Consumption in STOP MODE .............................................................................................. 0 mA
Operating temperature ..........................................................................................- 25°C + 85°C
Sound level of siren ................................................................................................(1 mt.) 114 dB
Self-supply autonomy ...................................................................................................5 minutes
Remote controls ...................................72 million billion variable codes (lithium battery)
Sensitivity of internal movement sensor .....................................................1,5° per second
Frequency of Mycro remote control .....................................................................433.92 MHz
Frequency of CARD B9.5 .................................................................................................2.45 GHz
EMERGENCY ‘OVERRIDE’ CODE to reset immobilizer and alarm functions
17. SPECIFICATIONS
Starter motor relay ......................................................................................................................10A
Direction indicator relay ....................................................................................................5A + 5A
Horn control .....................................................................................Negative electronic 300mA
18. CAPACTITY OF CONTROLS
Initial immunity phase ...............................................................................................26 seconds
Duration of alarm cycle ...............................................................................................26 seconds
Interval between alarm cycles .....................................................................................5 seconds
Passive arming delay ...................................................................................................50 seconds
STOP MODE delay ...................................................................................................................5 days
Intermittence of direction indicators ................................................0,4 sec. O /0,4 sec. On
19. TIMING
Contact alarm inputs ........................................................................................................10 cycles
Tilt sensor .............................................................................................................................10 cycles
Ignition sensing .................................................................................................................10 cycles
Cable tampering ..................................................................................................................9 cycles
20. ALARM CYCLES

Other manuals for Meta System DEFCOM 3.1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Meta System DEFCOM 3.1B and is the answer not in the manual?

Meta System DEFCOM 3.1B Specifications

General IconGeneral
BrandMeta System
ModelDEFCOM 3.1B
CategorySecurity System
LanguageEnglish

Related product manuals