DEFCOM 3.1B User Manual
The central unit arms automatically in 50 seconds after executed one of following operations:
After the motorcycles key has been turned OFF.
After the remote control has been pressed to disarm the alarm system.
After the alarm system has been disarmed using the ‘OVERRIDE’ CODE.
The passive arming is signaled by a short  ash of the direction indicators and a slow  ashing of
the LED, only the engine immobilizer is armed.
It is also possible to select the passive arming of all the alarm system (see the paragraph on
con guration). In this case, the signals given are the same as those of arming using the remote
control.
Press the A BUTTON of the remote control brie y within 50 seconds of turning the motorcycles
ignition key OFF; the direction indicators  ash twice. All the central unit’s functions have been
activated and the LED is  ashing.
Press the A BUTTON of the remote control for approximately 2 seconds and within 50 seconds
of turning the motorcycles ignition key OFF; the direction indicators  ash 2 + 1 times and the
siren emits 1 BEEP sounds.
All the central unit’s functions have been activated except the movement sensor. During the
immunity phase the LED  ashing fastly and after  ashes normally.
Press the A BUTTON of the remote control brie y: the direction indicators  ash once, the LED
switches o if no alarms have been triggered while the alarm system was active.
If the LED remains ON and the siren also emits a BOOP sound, this means that the alarm system
was triggered; To  nd out how the alarm was triggered, consult the MEMORISED ALARMS” ta-
ble in the chapter “1. NOTIFICATIONS”. If visual and acoustic signals are given during arming or
disarming that are di erent to those described above, consult the chapter “1.NOTIFICATIONS”
table to  nd out what they mean.
For the  rst 26 seconds after the alarm system has been armed with the remote control, the LED
ashing fastly to signal that it is possible to test the protection functions of the system.
Any alarm triggers do not provoke an alarm but just BEEP sounds by the siren together with
the resetting of the initial immunity phase which starts again. When this phase is over, the LED
ashes normally and any alarm triggers will provoke an alarm.
This is when the alarm system is armed and after the initial immunity phase is over. Any alarm
triggers will provoke an alarm cycle that lasts 26 seconds: the direction indicators  ash, the
siren emits a distinctive modulated sound, the horn will sound continuously and it will be im-
possible to start the engine.
2. PASSIVE ARMING
3. ARMING BY REMOTE CONTROL
4. ARMING WITHOUT ACTIVATING
THE INTERNAL MOVEMENT SENSOR
5. DISARMING
6. INITIAL IMMUNITY PHASE
7. ACTIVE PHASE

Other manuals for Meta System DEFCOM 3.1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Meta System DEFCOM 3.1B and is the answer not in the manual?

Meta System DEFCOM 3.1B Specifications

General IconGeneral
BrandMeta System
ModelDEFCOM 3.1B
CategorySecurity System
LanguageEnglish

Related product manuals