To lock and to release the keyboard
Keep UP and DOWN pressed for more than 3 seconds.
The ”oFF” message will be displayed and the keyboard will be locked. If any key is pressed more that
3 s. the ”oFF” message will be displayed.
To release the keyboard, keep UP an DOWN keys pressed till message ”ON” is displayed.
How to see the set temperature
Push an release the SET key, the set value will be showed.
Push and release SET, or wait for 5 s. to return to the normal visualization.
How to change the set point
Push the SET key for more than 2 seconds to change the set point value.
The value of the set point will be displayed and the ”°C” or ”F” led starts blinking.
To change the value, push Up or DOWN arrow within 10 s.
To memorize the new value, push the SET again or wait for 10 seconds.
How to start a manual defrost
Push DEFROST key for more than 2 seconds and a manual defrost will start.
|