7 Additional settings
7.8.2.3 Target position message window: "X
actual
=X
target
"
The tab Destination (target position) offers the following setting options:
Figure 102: "Signals" window - "Destination" tab
These parameters can be used to control the function X
actual
= X
target
of a digital output.
Figure 103: "Target position reached" message
The output will become active when the current position is within the range of (X
target
X
neg
.... X
target
+ X
pos
). However, it will only be activated if the position remains within
this range at least for the time that is specified under Response delay. The output will not
become inactive until the position leaves the range of the target window. For example, the
output remains active when a positioning run is started and the new target is still within the
target window.