12 Technical data
12.2 Power supply [X9]
Power data [X9]
Characteristic BL 4102-C BL 4104-C
Supply voltage 1 x 75 ... 230 VAC [± 10%], 50 ... 60 Hz
Supply network type TN, TT
Maximum mains current in
continuous operation
3 A 6 A
DC bus voltage 325 VDC (with U
mains
= 230 VAC)
24 V supply 24 VDC 20 %] (0.35 A)
*)
*)
plus the current consumption of a holding brake and I/Os (if included)
Additional information
l A slow-blow (B16), single-phase, 16 A automatic circuit breaker must be installed
in the mains power supply line.
l If low-voltage operation is necessary, we recommend using a series transformer
or isolating transformer for decreasing the voltage.
Internal braking resistor
Characteristic Value
Braking resistor
75
Peak power 2 kW
Continuous power 8 W
External braking resistor
Characteristic Value
Braking resistor
75
Nominal power 8 W
Peak power 2,5 kW
Additional information
The external braking resistor must be connected in parallel to the internal braking
resistor. As a result, the continuous power and pulse power can be doubled if a 75 Ω
resistor is used.
Product manual BL 4000-C Page 216 of 298