6 Applications
6.2.2 Destination parameters: general buttons
Parameters/Positioning/Destination parameters
Figure 47: "Destination parameters" window - "Settings" tab
The button Positioning settings can be used to change the general positioning settings
(e.g. the position limits) (see section 6.2.1 Global positioning settings on page 86).
The button GO! can be used to start a positioning run with the position set that is currently
displayed.
The button Copy can be used to copy all of the settings for a specific target position to
another target position. The following window will be displayed:
Figure 48: "Copy parameters of positions" window
You can copy a source position to a single target position. To do so, enter data into the two
upper fields. If you want to copy a position to several positions, activate the checkbox
Range to.... Then, enter the last target position into the third field.