NOTE: If there is a malfunction that is preventing the track driving, it must be fixed before
proceeding. If necessary, contact Metso.
In a problem situation, check if there are any active alarms.
1. If the alarm indicator (1) is red and pulsating, tap it.
Figure 9. Alarm view
2. Tap Alarms button (2) to see alarm descriptions. Red icon and text in the description indicate an active
alarm. By tapping any description row (3), you get specific information about the alarm/warning.
3. Fix the cause of the alarm(s). When the cause is fixed and the alarm can be signed off, brackets (4)
appear around the alarm symbol.
4. When all alarm causes are fixed, sign off the alarms by tapping Acknowledge all events button (5).
1.4 Driving with drive control device
WARNING
FIRE HAZARD
Can cause death or serious injury.
Always deactivate the diesel particulate filter regeneration before transporting the machine to a work
site, or into a cargo ship, or into any closed space. Also make sure that the filter soot load level is
below 60% before beginning the transportation of the machine. If the filter soot load level is 60% or
above 60%, perform the forced regeneration before beginning machine transportation. Before track
driving long distances, always perform the forced regeneration. Remember to activate the diesel
particulate filter regeneration again when the machine transportation is completed.
NOTE: Note that forced regeneration can take up to 1 hour to complete.
Lokotrack LT-series Driving instructions
10 (22) Copyright
©
Metso 2023. All rights reserved.
Project ID: Plant Code: Plant Unit Code: Document Type: Running No: Revision:
1
Metso Document ID:
D100018832