Pump priming assistance
In order to assist and optimise initial pump
priming, a bleed valve (32) has been integrated
on the left side of the DICE Module. The valve
allows evacuating potential trapped gas between
the pump outlet and the back pressure valve that
could be preventing the pump from priming.
In order to assist pump priming, slightly open the
bleed valve (32) by unscrewing it while the pump
is cycling until fluid starts passing through. Only
partial unscrewing is required. The Bleed valve
does not need to be (and should not be) fully
unscrewed to assist pump priming.
Then simply close the bleed valve and carry on with either the DICE
TM
set-up and
adjustment or the system normal operation.
Note: The bleed valve can also assist with pump priming if the pump loses prime during
normal operation.