6
3. Technical planning and installation of PV modules
3.1 Handling and transport
•Modulepalletsshouldonlybeloadedandmovedusing
suitableforklis.
•Theforklitruckmusthaveaminimumforklengthof
1.20m,aforklengthof1.75misrecommended.Theforks
mustbeselectedandplacedsothattheydonotcomeinto
contactwiththePVmodulesunderanycircumstances.
•Rideoverunevensurfacesslowly.
•Itisrecommendedtomovethepalletsoneatatimeand
notinadoubledeck.
•Palletsmaybestoredonadoubledeck(maximum2pallets
ontopofeachother).OnlytheoriginalMeyerBurger
palletsarepermittedforstacking.Itisessentialtoensure
thatthepalletsarepositionedexactlyontopofeachother.
•Nothird-partyproductsmaybeplacedorstackedonthe
palletsandPVmodules.
•Furthertransportrecommendationscanberequested
from Meyer Burger.
•ThePVmodulesmayonlybetouchedonthemodule
framewithcleangloves.
•WhenunpackingthePVmodules,thefrontsidemustbe
protectedagainstscratches,etc.
•ThecablesofthePVmodulesmustnotbeshort-circuited
(connected)underanycircumstances.
•Itisprohibitedtohandleandcarrythemodulebythe
cables and junction boxes.
•ClimbingonthePVmodulesandotherpointloads
(e.g.carryingthePVmodulesbytheirheadorback)
isprohibited,asthiscanleadtoirreversibledamage
tothePVmodules.
•Donotplacetoolsorotherobjectsontopofordropthem
ontothePVmodules.
• ThePVmodulesmustbestoreddryandprotectedfromthe
weatheruntilinstallation.Thetransportpalletsdonotprovide
sucientprotectionforoutdoorstorageofthePVmodules.
•WhenunpackingthePVmodulesfromthepallet,the
stabilityofthePVmodulesandpalletmustbeensured.
ThepalletandPVmodulesmustbesecuredagainst
fallingover.
•Thepackagingmustbedisposedofproperly.
3.2 Installation location
Thefollowinginformationontheinstallationlocationmustbe
observed:
ThePVmodulesmustnotbeinstalled:
In enclosed spaces
• Over2,000mabovesealevel*
• Onwatersurfaces*
• Inplaceswherewatercanaccumulate(e.g.ooding)
• Nearhighlyammablegasesorvapours
(e.g.gastanksorllingstations)
• Inplaceswherecontactofchemicalsubstances
(e.g.oilorsolvents)withpartsofthePVmoduleispossible
• Nearopenamesorammable/explosivematerials
• Intheimmediatevicinityofairconditioning
andventilationsystems
• ThePVmodulesmustnotbeusedasareplacement
forroofcoveringsorfacades.
• Forinstallationscloserthan500mtothesea,special
precautionsmustbetakenwithregardtogrounding,
maintenance and cleaning.
• ThePVmodulesmustnotbeindirectcontactwithsaltwater.
• Thereisanincreasedriskofcorrosionwheninstalling
PVmodulesinsaltyorammonia/sulphurousenvironments.
• UseofPVmodulesonmobileunitssuchasvehiclesand
shipswillvoidanyliabilityandwarrantyclaims.
• TheuseofPVmodulesforBIPVapplications(building-
integratedphotovoltaics)isnotpermitted*.
• TheuseofPVmodulesinconcentratedlightapplications
isprohibited.
*Installationabove2,000mabovesealevel,onwatersurfacesorinBIPVapplications
requiresconsultationwithandexplicitapprovalfromthemanufacturer.