MFJ-1278B MULTI-MODE OPERATIONAL COMMANDS
NODEPATH text string Mode: Mailbox Default:" "
Parameters:
text string; specifying node connect string
Enter the command the TNC will command the node connected by the NODEFORW
command to link with the receiving BBS.
Example:
cmd: NODEPATH C KB4VOL
cmd: NODEFORW PSL5
This sequence first connects to the PSL5 node. When connected, the TNC sends the node
connect command "C KB4VOL" to establish a link with the receiving bbs, KB4VOL.
NOMODE ON/OFF Mode: Packet Default: OFF
Parameters:
ON The MFJ-1278B will only switch modes (command, converse or transparent)
upon explicit command.
OFF The MFJ-1278B will switch modes in accordance with the setting of NEWMODE.
When NOMODE is ON, the MFJ-1278B will never change between CONVERSE or
TRANSPARENT mode to COMMAND mode (or vice-versa) on its own. Only user
commands (CONV, TRANS, or ^C) may change the type in mode.
If NOMODE is OFF, then automatic mode switching is handled according to the setting of
the NEWMODE command.
NUCR ON/OFF Mode: Packet Default: OFF
Parameters:
ON <NULL> characters are sent to the terminal following <CR> characters.
OFF
<NULL> characters are not sent to the terminal following <CR> characters.