MFJ-1278B MULTI-MODE APPENDIX H COMMAND SUMMARY
Command Paramete
r
Default Mode Function Page
LFADDALT
ON|OFF on RTTY Enables the MFJ-1278B to go to the next
line when a <CR> character is received in
RTTY mode.
6-67
LFIGNORE
ON|OFF off Packet Line feeds are ignored except in
transparent mode.
6-68
LISTEN
-- I-command AMTOR Used to monitor someone else's Mode A
AMTOR connection.
6-68
MAILbox
ON/OFF off Pactor determines if Pactor Mailbox is on-line. 6-68
MAILBOX
ON|OFF on Packet Enables the Packet personal mailbox. 6-69
MAILLED
ON|OFF on Packet Controls the STA/MAIL LED. Flashes
when mail is presence.
6-70
MALL
ON|OFF on Packet Determines the class of packets which are
monitored.
6-71
MARSMODE
n 0 RTTY/ASCII Use with Promars command to set the
type of MARS QSO.
6-72
MATCH
ON|OFF on AMTOR Used for selectively monitoring portions
of mode B FEC transmissions.
6-73
MAXFRAME
n 4 Packet Sets the upper limit for the outstanding
packets that can occur at one time.
6-73
MAXSum
nn 30 Pactor Specifies the number of cycles of error-
ladden information packets received.
6-74
MAXUp nnn 10 Pactor Specifies the number of good 100 baud
packets before a SPEEDUP is requested.
6-74
MBEGIN
cccc <<>> AMTOR Allows the display of mode B
transmissions only after the reception of
the beginning of the signal.
6-74
MCOM
ON|OFF off Packet Enables monitoring of connected and
disconnected packet when monitor is on.
6-75
MCON
ON|OFF off Packet Allows the monitoring of other packets
while connected to another station.
6-75
MCTEXT
text blank Packet Allows storing of text messages to be
stored for mailbox. Text is sent when
mailbox is connected.
6-76
MEND
cccc nnnn AMTOR Used with MBEGIN and MATCH and the
mode B receiving end when the MEND
string is received
6-76.
MFILTER
n1-n4 $00 M-Packet Allows you to eliminate certain characters
from received packets.
6-76
MHCLEAR
-- I-command Packet Clears the MHEARD list. 6-77
MHEARD
-- I-command Packet A list of all monitored packet stations. 6-77
MODE
-- I-command All Selects the operation mode of the MFJ-
1278B.
6-77
MNONAX25
ON|OFF off Packet Allows MFJ-1278B to monitor non AX.25
packet.
6-78
MNONPRIN
ON|OFF on Packet Determines whether monitored packets
containing non-printable characters are
monitored or discarded.
6-78

Table of Contents