MFJ-1278B MULTI-MODE APPENDIX H COMMAND SUMMARY
Command Paramete
r
Default Mode Function Page
PACTIME
n10 Packet Determines the
length of time
between transmit
and receive.
6-92
PARITY
n 0 Packet Sets the parity mode for terminal or
computer data transfer.
6-92
PASS
n $16 (^V) Packet Selects the ASCII character used for the
"pass" input editing character.
6-93
PAss
nnn $16 Pactor Same as the PASS command in other
modes.
6-93
PASSALL
ON|OFF off Packet Causes the MFJ-1278B to display packets
received with invalid CRC fields.
6-94
PIXTONES
n -- FAX/SSTV Sets transmit tones for multi-level
FAX/SSTV pictures.
6-95
PKTPIX
ON|OFF off Packet Allows the MFJ-1278B to print packet
pictures to the built-in printer port.
6-97
PRINTGRA
ON|OFF on FAX/SSTV Determines whether the MFJ-1278B will
print the graphics to the printer or the
terminal screen.
6-98
PRINTER
ON|OFF off All Turns the parallel printer port on or off. 6-98
PRINTTES
-- I-command All Used to test the printer connected to the
parallel printer port.
6-99
PROFMARS
-- I-command RTTY/ASCII Invokes pre-set commands for MARS
operation.
6-99
PTOver
nnn I-command Pactor Designates the Pactor changeover
character.
6-99
PTSend
-- I-command Pactor Same as issuing the U1 unproto
command.
6-100
QRT
-- I-command AMTOR Used to break a link in AMTOR. 6-100
R
-- I-command AMTOR Is the equivalent to QRT. 6-100
RADIO
n 1 ALL Allows the user to select the radio port on
the MFJ-1278.
6-100
RANDOMCW
ON|OFF off CW Allows the used of the random code
generator.
6-101
RBITMASK
$xx 0 RTTY/ ASCII Set the bit inversion during receiving data 6-101
RECONNECT
call1-9 I-command Packet Used to change the path through which
you are currently connected to a station.
6-101
REDISPLA
n $12 (^R) All Used to change the redisplay-line input
editing character.
6-102
REMSYSOP
call 0-15 blank M-Packet Permits the SYSOP to perform sysop
functions remotely.
6-102
RESTART
-- I-command Packet Re-initializes the MFJ-1278B using the
stored parameters.
6-103
RESET
-- I-command All Resets all parameters to their default
values and reinitiates the unit.
6-103
RESPTIME
n 0 Packet Sets a minimum delay that is imposed on
acknowledging packets.
6-103

Table of Contents