EasyManua.ls Logo

MHG Heating ProCon 16 - Buffer Storage Tank; Setpoint

Default Icon
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© MHG Heating Ltd
75
MHG Heating Ltd Unit 4 Epsom Downs Metro Centre, Waterfield, Tadworth, Surrey KT20 5LR
Telephone 08456 448802 Fax 08456 448803 Email info@mhgheating.co.uk
Web www.mhgheating.co.uk
010711
function gradient
3840
Collector frost
protection temp
------- °C
3850
Collector
overtemperature
protection
------- °C
3860
Evaporation
temperature of heat
carrier
------- °C
3880
Type of antifreeze
added
None (water)
3881
Antifreeze
concentration
30 %
3884
Volumetric flow solar
pump
200 l/h
Solid fuel boiler
Line no. Data point Value Unit
4102
Solid fuel boiler locks
other producers
On
4110
Min solid fuel boiler
setpoint
40 °C
4130
Temp differential on
solid fuel boiler
8 °C
4131
Temp differential off
solid fuel boiler
4 °C
4133
Comparative
temperatur solid fuel
boiler
Setpoint min
4140
Pump overrun time
solid fuel boiler
20 min
4141
Overtemperature
drop solid fuel boiler
90 °C
4170
Frost protection for
plant solid fuel boiler
Off
Buffer tank
Line no. Data point Value Unit
4720
Automatic producer
lock
With B4
4721
Automatic producer
lock switching
differential
8 °C
4722
Diff. Buffer/HC temp
to producer release
-5 °C
4723
Temp diff buffer/CC
to source release
0 °C
4724
Min buffer temp
while heating mode
------- °C
4726
Max buffer temp
while cooling mode
25 °C
4739
Buffer stratification
protection
Off
4740 Buffer stratification 5 °C