4 | REMOTE POWER PACK SERVICE MANUAL MICROMATIC.COM | 866-327-4159
EQUIPMENT SPECIFICATIONS
MODEL MMPP4302-R MMPP4302-PKG-R MMPP4303-PKG-R MMPP4303-PKG-3-R MMPP4305-PKG-R
Type Air Cooled Air Cooled Air Cooled Air Cooled Air Cooled
BTUs* 3,600 3,600 5,100 5,100 7,250
Compressor HP 1/2 1/2 3/4 3/4 1
Glycol Pumps 1 2 2 3 2
Pump Type
Rotary Vane Rotary Vane Rotary Vane Rotary Vane Rotary Vane
Pump GPH
80 80 80 80 80
Pump Motor HP
1/3 1/3 1/3 1/3 1/3
Pump Inlet/Outlet Barbs 9.52mm (3/8”) 9.52mm (3/8”) 9.52mm (3/8”) 9.52mm (3/8”) 9.52mm (3/8”)
Plug Type
5-15P 5-15P 6-15P 6-15P 6-15P
Condensing Unit
Electrical Requirement
115V / 20A 115V / 20A 208/230V / 20A 208/230V / 20A 208/230V
Refrigerant R134a R134a R134a R134a R134a
Refrigerant
Running Pressures
18 (low) / 140 (high)
18 (low)
140 (high)
18 (low)
140 (high)
18 (low)
140 (high)
18 (low)
140 (high)
Dimensions
L x W x H Including
pump(s) and motor(s)
30" x 18"x 29.75” 30” x 18”x 29.75” 30” x 18”x 29.75” 30" x 18" x 29.75" 37.12" x 18.75" x 31.15"
Weight (lbs) 71 kg / 157 lbs 71 kg / 157 lbs 80 kg / 175 lbs 91 kg / 200 lbs 98 kg / 215 lbs
Bath Capacity (gal) 11.5 gal / 43.5 L 11.5 gal / 43.5 L 11.5 gal / 43.5 L 11.5 gal / 43.5 L 11.5 gal / 43.5 L
Bath Insulation
Thickness
1.5" 1.5" 1.5" 1.5" 1.5"
Inlet Water Pressure NA NA NA NA NA
Water Inlet & Outlet Fitting NA NA NA NA NA
Minimum Water Pipe Size NA NA NA NA NA
Approval
ETL Listed ETL Listed ETL Listed ETL Listed ETL Listed
*Rated at 20° F evaporator temperature and 90° F ambient temperature. †.3GPM, water is only used when the temperature of the condenser rises high enough
to open the cooling inlet valve. This is approximately 40% of the operating time depending on the ambient temperature and usage. Condenser Inlet Water
Temperature: Minimum 45° F / Maximum 80° F