5Microlife BP W100 – MAM Wrist EN
symbol is permanently displayed and the device is now set to MAM
mode (automatic triple measurement).
MAM-Mode
In MAM mode, 3 measurements are automatically taken in
succession and the result is then automatically analysed and
displayed. Because the blood pressure constantly fluctuates, a
result determined in this way is more reliable than one produced
by a single measurement.
After pressing the ON/OFF button 1, the MAM-symbol AT
appears in the display.
The bottom, right hand section of the display shows a 1, 2 or 3 to
indicate which of the 3 measurements is currently being taken.
There is a break of 15 seconds between the measurements
(15 seconds are adequate according to «Blood Pressure Moni-
toring, 2001, 6:145-147» for oscillometric instruments). A count
down indicates the remaining time and a beep will sound
5 seconds before the 2nd and 3rd readings will begin.
The individual results are not displayed. Your blood pressure will
only be displayed after all 3 measurements are taken.
Do not remove the cuff between measurements.
If one of the individual measurements was questionable, a fourth
one is automatically taken.
3. Taking a blood pressure measurement
Checklist for taking a reliable measurement
1. Avoid activity, eating or smoking immediately before the
measurement.
2. Sit down on a back-supported chair and relax for 5 minutes. Keep
your feet flat on the floor and do not cross your legs.
3. Always measure in a sitting position and on the same wrist. Use
the wrist which usually shows higher blood pressure values.
4. Remove any items of clothing and your watch, for example, so
that your wrist is free.
5. Always ensure that the cuff is positioned correctly, as shown in
the pictures illustrated on the short instruction card.
6. Fit the cuff comfortably but not too tight. The cuff will cover a wrist
circumference according to the information in the «Technical
specifications».
7. Support your arm in a relaxed position and ensure that the device
is at the same height as your heart.
8. Press the ON/OFF button 1 to start the measurement.
9. The cuff will now pump up automatically. Relax, do not move and
do not tense your arm muscles until the measurement result is
displayed. Breathe normally and do not talk.

Table of Contents

Other manuals for Microlife BP W100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Microlife BP W100 and is the answer not in the manual?

Microlife BP W100 Specifications

General IconGeneral
BrandMicrolife
ModelBP W100
CategoryBlood Pressure Monitor
LanguageEnglish

Related product manuals