10.When the correct pressure is reached, the pumping stops and the
pressure falls gradually. If the required pressure was not reached,
the device will automatically pump some more air into the cuff.
11.During the measurement, the heart symbol AM flashes in the
display and a beep sounds every time a heartbeat is detected.
12.The result, comprising the systolic 6 and the diastolic 7 blood
pressure and the pulse rate 8 is displayed and a long beep is
heard. Note also the explanations on further display symbols in
this booklet.
13.Remove and switch off the monitor and enter the result in the
enclosed blood pressure pass. (The monitor does switch off auto-
matically after approx. 1 min.).
4. Appearance of the irregular heartbeat (IHB) symbol
This symbol AK indicates that an irregular heartbeat was detected.
In this case, the measured blood pressure may deviate from your
actual blood pressure values. It is recommended to repeat the
measurement.
5. Data memory
This device always stores the last result at the end of the measure-
ment. To recall the reading, press and hold the ON/OFF button 1
while the device is switched off. All display elements are shown now.
Release the button when the stored result with the letter «M» 9 is
displayed.
6. Battery indicator and battery change
Low battery
When the batteries are approximately ¾ empty the battery symbol
AL will flash as soon as the device is switched on (partly filled battery
displayed). Although the device will continue to measure reliably,
you should obtain replacement batteries.
You can stop the measurement at any time by pressing the
ON/OFF button or open the cuff (e.g. if you feel uneasy or an
unpleasant pressure sensation).
Information for the doctor in case of repeated appearance of
the IHB symbol:
This device is an oscillometric blood pressure monitor that also
measures the pulse during blood pressure measurement and indi-
cates when the heart rate is irregular.

Table of Contents

Other manuals for Microlife BP W100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Microlife BP W100 and is the answer not in the manual?

Microlife BP W100 Specifications

General IconGeneral
BrandMicrolife
ModelBP W100
CategoryBlood Pressure Monitor
LanguageEnglish

Related product manuals