10
CONTENTS & FIELD SIZE
REMARKS
User 24 code (4 digits)
Installer code (4 digits)
Default 0000
Area A account (4 digits)
Area B account (4 digits)
Auto-arming time (4 digits) See also Locs 347,412
Default 9999
Upload/download password (4 digits)
Default 5555
Test signal time (4 digits)
Default 9999
The following locations are used for Contact-ID reporting codes. Erasing one of these
locations disables reporting of that event in ALL formats. The first digit is fixed,
the remaining two digits are programmable.
(Non Contact-ID reporting codes follow this section)
Zone 1 alarm and restore code (2 digits, prefix 1)
Default 30 = 130
Zone 2 alarm and restore code (2 digits, prefix 1)
Default 30 = 130
Zone 3 alarm and restore code (2 digits, prefix 1)
Default 30 = 130
Zone 4 alarm and restore code (2 digits, prefix 1)
Default 30 = 130
Zone 5 alarm and restore code (2 digits, prefix 1)
Default 30 = 130
Zone 6 alarm and restore code (2 digits, prefix 1)
Default 30 = 130
Zone 7 alarm and restore code (2 digits, prefix 1)
Default 30 = 130
Zone 8 alarm and restore code (2 digits, prefix 1)
Default 30 = 130
Zone bypass code (2 digits, prefix 5)
Default 70 = 570
Reserved (2 digits)
Reserved (2 digits)
Zone transmitter low battery (2 digits, prefix 3)
Default 84 = 384
User open/close code (2 digits, prefix 4)
Default 01 = 401
User last close/first open code (2 digits, prefix 4)
Disabled
User pendant battery low code (2 digits, prefix 3)
Default 84 = 384
User duress code (2 digits, prefix 1)
Default 21 = 121
User night panic code (2 digits, prefix 1)
Default 20 = 120
User 2-key panic code (2 digits, prefix 1)
Default 20 = 120
User Fire panic code (2 digits, prefix 1)
Default 10 = 110
User medical panic code (2 digits, prefix 1)
Default 00 = 100
User arming failure code (2 digits, prefix 4)
Default 54 = 454
Reserved
User code changed (2 digits, prefix 3)
Default 06 = 306
User initiated test code (2 digits, prefix 6)
Default 01 = 601
Line fault code (2 digits, prefix 3)
Default 51 = 351
Comms fail code (2 digits, prefix 3)
Default 54 = 354
AC Power failure code (2 digits prefix 3)
Default 01 = 301
Battery test fail code (2 digits, prefix 3)
Default 02 = 302
Test signal code (2 digits, prefix 6)
Default 02 = 602
Auxiliary power overload (2 digits, prefix 3)
Default 12 = 312
Siren output fault (2 digits, prefix 3)
Default 20 = 320
Reserved (2 digits)
Program accessed or altered (2 digits, prefix 6)
Default 27 = 627
Clock setting changed code (2 digits, prefix 6)
Default 25 = 625
Reserved (2 digits)
Reserved (2 digits)
The following locations are used for non-contact-ID formats.
Zone 1 alarm code and zone ID (2 digits)
Zone 2 alarm code and zone ID (2 digits)
Zone 3 alarm code and zone ID (2 digits)
Zone 4 alarm code and zone ID (2 digits)
Zone 5 alarm code and zone ID (2 digits)
Zone 6 alarm code and zone ID (2 digits)
Zone 7 alarm code and zone ID (2 digits)
Zone 8 alarm code and zone ID (2 digits)
Night panic code (2 digits)
Two key panic code (2 digits)
Fire panic code (2 digits)

Other manuals for Micron Scorpion Z6020C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Micron Scorpion Z6020C and is the answer not in the manual?

Micron Scorpion Z6020C Specifications

General IconGeneral
BrandMicron
ModelScorpion Z6020C
CategoryNetwork Router
LanguageEnglish

Related product manuals