4.7.3 Error messages in alphabetical order and suggested action
!CURR/VOLT-CODE The programmed value of shunt or voltage code is not
valid.
Measures: Check and reprogram the shunt or voltage
code.
ACID CIRC. ERROR Only if acid circulation is activated Requires hardware.
The air pressure was too high or too low during the main
charging. The charging factor for standard battery is
used.
Possible causes: The air hose is not connected. Leakage.
Folded hose. Air pump failure.
Measures: Check airpump, connections and hoses.
Ah-LIM. EXCEEDED The charged capacity exceeds the programmed value of
battery capacity during the I1 or U1-phase. The I1 or U1-
phase is terminated and the I2-phase is started.
Possible causes: Incorrect value programmed. Warm
battery. Faulty cell. Deep discharged battery.
Measures: Check battery. Check programming.
ALGORITHM ERROR Programmed value of charging curve is unknown for the
charger.
Measures: Program correct value in ”set charging
algorithm” under ”service”
BATT.ID UNKNOWN Only if IDB-function is activated. Requires hardware.
The ID of the battery is unknown to the charger.
Possible causes: The ID of the battery is not
programmed.
Measures: Read the battery ID and program the ID and
its corresponding data into the memory. See separate
instruction for the IDB system
BATTERY FAULT dI Only if the function is activated in “Control register 1”
The current is not decreasing during the U1-phase. The
U1-phase is terminated and the I2-phase is started.
Possible causes: Warm battery. Faulty cell. Other battery
problems.
Measures: Check the battery.