Flame mode
2-3 display and state
LED display
U: plasma mode, range 30~250
C: flame mode, range 3~30
E: sensitivity, range 1~10
b: initial location height/pierce, range 1~20mm
H: maximum adjustment speed when auto cutting, 5~50