For 36K-48K Outdoor Unit 
Communication malfunction between indoor and outdoor units 
Current overload protection 
Outdoor ambient temperature sensor (T4 ) malfunction 
Condenser coil temperature sensor (T3) malfunction 
Compressor discharge temperature sensor (T5) malfunction 
Outdoor unit EEPROM parameter error 
Outdoor fan speed malfunction 
Inverter module (IPM) malfunction 
Over-voltage or under-voltage protection 
Compressor top high temperature protection (OLP) 
Low ambient temperature cut off in heating 
Compressor drive malfunction 
High temperature protection of indoor coil in heating 
Outdoor temperature protection of outdoor coil in cooling 
Temperature protection of compressor discharge 
Communication malfunction between control board and IPM board 
Outdoor IPM module temperature sensor malfunction 
 
Outdoor check function 
Display  running  frequency,  running  state  or  malfunction 
code 
Indoor unit capacity demand code 
Actual data*HP*10 
If capacity demand code is higher than 99, the digital display 
tube will show single digit and tens digit. (For example, the 
digital display tube show “5.0”,it means the capacity demand 
is  15.  the  digital  display  tube  show  “60”,it  means  the 
capacity demand is 6.0) 
Amendatory capacity demand code 
The frequency after the capacity requirement 
transfer 
The frequency after the frequency limit 
The frequency of sending to 341 chip 
Indoor unit evaporator outlet temp.(heating T2,
cooling T2B) 
If the temp. is lower than 0 degree, the digital display tube 
will show “0”.If the temp. is higher than 70 degree, the digital 
display tube will show “70”. 
If the temp. is lower than -9 degree, the digital display tube