Service Manual_2020-V1.0
37
9.2 Temperature control
A. Single freezing model
Temperature setting of freezing chamber
The temperature setting range of freezer chamber is -24℃~-16℃ (10℉~-11℉). The temperature can
be set circularly, press the button “-” or “+” once, the temperature turn by 1℃/℉. The setting is effective
after being locked.-14℃→ -13℃→……...→ -20℃→ -21℃→ -20℃→……..→ -14℃
6℉→5℉→……→-5℉→-6℉→-5℉→……→5℉→6℉
B. Refrigeration / freezing conversion model
9.2.1Temperature setting of refrigerating chamber
The temperature setting range of refrigerating chamber is 2℃ ~ 8℃ (35℉~46℉), the temperature
can be set circularly, press the button “∨” or “∧” once, the temperature turn by 1℃/℉. The setting is
effective after being locked.
8℃→7℃→……...→2℃→3℃→……..→8℃
46℉→45℉→44℉→……→35℉→36℉→……→46℉
9.2.2Temperature setting of freezing chamber
The temperature setting range of freezer chamber is -24℃~-16℃ (10℉~-11℉). The temperature can
be set circularly, press the button “∨” or “∧” once, the temperature turn by 1℃/℉. The setting is
effective after being locked.-12℃→ -13℃→……...→ -24℃→ -23℃→ -22℃→……..→ -12℃
10℉→9℉→8℉→……→-10℉→-11℉→-10℉→……→9℉→10℉
9.3 Mode setting
9.3.1Super freeze mode