18
instructions (except for the RO membrane filter).The RO membrane filter shall be
flushed through the mode that repeatedly supply and cut off power of the whole
machine for 10 times, and hold for 25 seconds each time.
5. Open the lower door, remove the old filter to be replaced, and replace it with a new
filter. Note that the filter must be installed in place.
6. Lock the lower door with the original screws.
7. Filter forced reset setting
Hold the cold water button + warm water button for 3 seconds to enter the filter reset
mode. The first filter indicator and name begin to flash, the digital tube does not flash
to display the remaining percentage of life, hold the cold water button for 3 seconds to
reset the filter, and the filter life recovers to 100%, press the cold water button to
display the next filter, operate to reset and switch to the next filter with the same step,
at the last filter, press the cold water button to exit the filter reset setting. The water
output buttons are used as normal. During the filter reset process, if no button is
pressed for 30 seconds, the filter reset mode is automatically exited. The filter life is
accumulated in hours according to the power-on time, and is saved after power-off.
Note: In the filter reset mode, press the water output button, the system will not output
water, after exiting the filter reset mode, the water output control function is restored.
Maintenance
1. Keep this machine in a dry and cool place and avoid direct sunshine. Rearward of
the machine shall be at least 25 cm away from the wall. Never put the machine on
paper or foam, which may store water and then cause creepage. Never put anything
flammable beside this machine. Do not use the machine outdoors or in a place that
can be splashed by water.
2. For the water purifier, the installation and replacement of filters must be carried out
by qualified personnel.