3. In case the machine is not in use for a long time, turn off the heating switch or the
refrigerating switch to save power.
4. In case the machine is not needed for a long time, please take off the plug, turn off
the copper chrome-plated ball valve and drain off the remaining water through the
outlet. For another use, discharge water for 10 min. In the event that the machine is
blocked by ice due to the environment below ice point, keep the refrigerating switch
closed for 4 hours and then turn it on to continue the operation.
5. In case the water supply is cut off, please close the feed water ball valve and cut off
the power, after water re-supply, please open the other faucets to discharge sediment
and then turn on the feed water ball valve.
6. The machine must use an earthed three-pin socket and a reliable creepage
protection switch.
7. Never use organic solvents such as gasoline to clean the machine: strictly prohibit
washing the machine with water or splashing water to the machine.
8. Never turn on (off) the machine by inserting the plug into (pulling the plug out
from) the socket. Never increase the length of the supply cord to avoid fire.
9. If the supply cord is damaged, it must be replaced by the manufacturer or qualified
person so as to avoid a hazard.
10. The water source for the water purifier is civil tap water.
11. Never dismantle spare parts of the machine to avoid water leakage or damage.
12. Never turn the machine upside down or lean it more than 45° when moving it so
as to avoid any damage to it or any accident.
13. Limited warranty: electrical components and water system are warranted for 12
months from date of purchasing.
Trouble shooting
In case of failure, please carry out inspection according to the requirements below. If
unresolved, please contact the local service agency.
Continuously start and stop the product
for 5 times at 40 seconds intervals to
automatically flush the filtration system,
and feed and discharge the water from
the water storage system according to the
first step of the Clean Maintenance; after
that, the output water can be used
normally