M‐ThermalSplit
20190971
4.19 P6Troubleshootingforsingle‐phasemodels
Digitaldisplayoutput
Description
Invertermoduleprotection.
M‐ThermalSplitstopsrunning.
ErrorcodeP6isdisplayedontheuserinterface.SpecificerrorcodeL0,L1,L2,L4,L5,L7,L8orL9isdisplayedonthe
outdoorunitmainPCB.
Possiblecauses
Invertermoduleprotection.
DCbusloworhighvoltageprotection.
MCEerror.
Zerospeedprotection.
Phasesequenceerror.
Excessivecompressorfrequencyvariation.
Actualcompressorfrequencydiffersfromtargetfrequency.
SpecificerrorcodesforP6invertermoduleprotection
IfaP6errorcodeisdisplayedontheuserinterface,oneofthefollowingspecificerrorcodesisdisplayedontheoutdoor
unitmainPCB:L0,L1,L2,L4,L5,L7,L8,L9.RefertoTable4‐4.1.
Table4‐4.1:SpecificerrorcodesforerrorP6
Specificerrorcode Content
L0 Invertermoduleprotection
L1 DCbuslowvoltageprotection
L2 DCbushighvoltageprotection
L4 MCEerror
L5 Zerospeedprotection
L7 Phasesequenceerror
L8 Compressorfrequencyvariationgreaterthan15Hzwithinonesecondprotection
L9 Actualcompressorfrequencydiffersfromtargetfrequencybymorethan15Hzprotection
ThespecificerrorcodescanalsobeobtainedfromtheLEDindicatorsLED1/LED2ontheinvertermodule.RefertoFigure
4‐4.2andFigure4‐2.4or4‐2.6inPart4,2.1“OutdoorUnitPCBs”.
