Compressor
Running
Frequency Fr
press "On/Off" for 2s to enter Twins Selector, the code displayed is “Ch”,
press "OK" to send the Query Twins Selector code; press the Up/Down
key to select, 0 indicates that there is no Twins, 1 indicates the host, and 2
indicates the slave. Press "OK" to confirm, and press "On/Off" for 2s to
exit.
Press "On/Off" for 2s to enter the Static Voltage Selector, the code
displayed is “Ch”, press "OK" to send the Query Static Voltage Selector
code; press the Up/Down key to select the static voltage values of 0 to 4
or AF (constant air volume test). Press "OK" to confirm, and press
"On/Off" for 2s to exit.
Current indoor
capacity test state
Sn
press "On/Off" for 2S to enter the Min. Desired Cooling Frequency
Selector, the code displayed is Ch, press "OK" to send the Query Min.
Desired Cooling Frequency Selector code; press the Up/Down key to
select the minimum cooling frequency desired and press "OK" to confirm;
press "On/Off" for 2s to exit.
Set Speed Pr of the
outdoor fan
press "On/Off" for 2s to enter the Min. Desired Heating Frequency
Selector, the code displayed is “Ch”, press "OK" to send the Query Min.
Desired Heating Frequency Selector code; press the Up/Down key to
select the min. desired heating frequency value, press "OK" to confirm;
and press the "On/Off" for 2s to exit.
press "On/Off" for 2s to enter the Max. Running Frequency Selector of
the restricted area 6 in the cooling mode T4, the code displayed is “Ch”,
press "OK" to send the Query Max. Running Frequency Selector code of
the restricted area 6 in the cooling mode T4; press the Up/Down key to
select the limit, then press "OK" to confirm; and press "On/Off" for 2s to
exit.
Actual Running
Speed ir of the
indoor fan
press "On/Off" for 2s to enter the Outdoor Forced Running Frequency
Selector, the code displayed is “Ch”, press "OK" to send the Query
Outdoor Forced Running Frequency Selector code; press the Up/Down
key to select the outdoor forced running frequency, then press "OK" to
confirm; and press "On/Off" for 2s to exit.
Set Temperature
TT after
compensation
press "On/Off" for 2s to enter One-Key Recovery, the code displayed is
“rS”, then press "OK" to send the One-Key Recovery code, the mode
selector of the remote control will recover to "Cooling and heating", the
min. temperature recovers to 16°C, and the max. temperature recovers to
30°C; and press "On/Off" for 2s to exit.